Use of an image intensifier for the localization and removal of a foreign body in the lower lip

Autores

  • Gabriel Mulinari-Santos
  • João Paulo Bonardi
  • André Luís da Silva Fabris
  • Igor de Oliveira Puttini
  • Juliana Zorzi Coléte
  • Ciro Borges Duailibe-de-Deus
  • Leonardo Perez Faverani
  • Idelmo Rangel Garcia Júnior
  • Francisley Ávila Souza

DOI:

https://doi.org/10.21270/archi.v7i6.3008

Resumo

Foreign bodies can be found in the soft tissues of the face and in the maxillary bones in routine radiographic examinations. In the majority they do not present symptomatology. The removal of foreign bodies without the accurate location can cause severe complications. We present a case of 44-year-old male complaining an unusual foreign body in the lower lip region. Radiography did not reveal the exact location, and did not let a resolution at first time. Subsequently, the surgical treatment was effective with the aid of navigation-assisted fluoroscopy that showed the precise location of the foreign body for removal and avoided more discomfort to the patient.

Descriptors: Foreign Bodies; Fluoroscopy; Traumatology.

Downloads

Não há dados estatísticos.

Referências

Rudagi BM, Halli R, Kini Y, Kharkhar V, Saluja H. Foreign bodies in facial trauma-report of 3 cases. J Maxillofac Oral Surg. 2013; 12(2):210-3.

Bhatt C, Reddy NV, Reddy TN. Removal of sub-mucosal foreign body (metal wire) from the pharynx using image intensifier, J Laryngol Otol. 2003; 117(11):902-4.

Nezafati S, Shahi S. Removal of broken dental needle using mobile digital C-arm. J Oral Sci. 2008; 50(3):351-3

Pandyan D, Nandakumar N, Qayyumi BN, Kumar S. C-arm fluoroscopy: a reliable modality for retrieval of foreign bodies in the maxillofacial region. J Contemp Dent Pract. 2013; 14(6):1193-6.

Gui H, Yang H, Shen SG, Xu B, Zhang S, Bautista JS. Image-guided surgical navigation for removal of foreign bodies in the deep maxillofacial region. J Oral Maxillofac Surg. 2013; 71(9):1563-71.

de Mey J, Op de Beeck B, Meysman M, Noppen M, De Maeseneer M, Vanhoey M et al., Real time CT-fluoroscopy: diagnostic and therapeutic applications, Eur J Radiol. 2000; 34(1):32-40.

Takahashi M, Bussaka H, Nonaka N, Miura G, Hirata Y, Matsukado Y. Digital fluoroscopic angiography in the diagnosis of central nervous system diseases. Neurol Med Chir. 1983; 23(2):116-22.

Zhao JB, Chen Y, Zeng QL, He XF, Lu W, Mei QL, Li, YH. Removal of metallic foreign body in the soft tissue under fluoroscopy: 10 years of experiences. Nan Fang Yi Ke Da Xue Xue Bao. 2009; 29(12):2504-5, 2509.

Sencimen M, Bayar GR, Gulses A. Removal of the retained suture needle under C-arm fluoroscopy: a technical note. Dent Traumatol. 2010; 26(6):527-9.

Sri-Pathmanathan R. The mobile X-ray image intensifier unit in maxillofacial surgery. Br J Oral Maxillofac Surg. 1990; 28(3):203-6.

Gans BJ, Kallal RH, Helgerson AC, Verona SR. The image intensifier in oral and maxillofacial surgery. J Oral Maxillofac Surg. 1982; 40(11):726-9.

Park SS, Yang HJ, Lee UL, Kwon MS, Kim MJ, Lee JH et al. The clinical application of the dental mini C-arm for the removal of broken instruments in soft and hard tissue in the oral and maxillofacial area. J Craniomaxillofac Surg. 2012; 40(7):572-8.

Yoganathan P, Conti SM, Kavalec C. The use of intraoperative fluoroscopy as an aid for removal of radiopaque intraorbital foreign bodies. Ophthalmic Surg Lasers Imaging. 2008; 39(5):436-7.

Su Y, Nan G. Using methylene blue as a marker to find and remove tiny metallic foreign bodies embedded in the soft tissues of children: a randomised controlled trial. Int J Surg. 2016; 29:43-8.

Downloads

Publicado

2018-07-17

Como Citar

Mulinari-Santos, G., Bonardi, J. P., Fabris, A. L. da S., Puttini, I. de O., Coléte, J. Z., Duailibe-de-Deus, C. B., Faverani, L. P., Garcia Júnior, I. R., & Souza, F. Ávila. (2018). Use of an image intensifier for the localization and removal of a foreign body in the lower lip. ARCHIVES OF HEALTH INVESTIGATION, 7(6). https://doi.org/10.21270/archi.v7i6.3008

Edição

Seção

Artigos