Moldagem Tripla com Silicones de Adição - Relato de Técnica

Autores

  • Mauthos Sepini Mestrando, Programa de Pós-Graduação em Ciências Odontológicas, Universidade Federal de Alfenas (UNIFAL) 37130-000 Alfenas - MG, Brasil https://orcid.org/0009-0006-2730-5981
  • Kélisson Duarte Reis Mestrando, Programa de Pós-Graduação em Ciências Odontológicas, Universidade Federal de Alfenas (UNIFAL) 37130-000 Alfenas - MG, Brasil https://orcid.org/0009-0006-9288-8458
  • Lísia Aparecida Costa Gonçalves Professora Doutora, Programa de Pós-Graduação em Ciências Odontológicas, Universidade Federal de Alfenas (UNIFAL) 37130-000 Alfenas - MG, Brasil https://orcid.org/0000-0002-2879-4055
  • Frederico dos Reis Goyatá Professor Doutor, Programa de Pós-Graduação em Ciências Odontológicas, Universidade Federal de Alfenas (UNIFAL) 37130-000 Alfenas - MG, Brasil https://orcid.org/0000-0002-7877-2188

DOI:

https://doi.org/10.21270/archi.v14i8.6627

Palavras-chave:

Materiais Dentários, Silicones, Materiais para Moldagem Odontológica, Técnica de Moldagem Odontológica, Prótese Dentária, Coroas

Resumo

Este trabalho apresenta um relato de caso clínico demonstrando a técnica de moldagem tripla com silicone de adição utilizando-se em três consistências do material de moldagem, aplicada na reabilitação protética com coroa total em dente posterior. O objetivo desta técnica foi obter uma cópia fiel do preparo, com foco na precisão da adaptação marginal da peça protética. A técnica detalha o uso sequencial do silicone de adição em diferentes viscosidades, visando potencializar a reprodução dos detalhes anatômicos do preparo. Considerada uma modificação das técnicas tradicionais, especialmente a de dois passos, esta abordagem demonstrou ser eficaz na prática clínica para casos que exigem máxima precisão, oferecendo resultados previsíveis e de alta qualidade.

Downloads

Não há dados estatísticos.

Referências

1. Chugh A, Arora A, Singh VP. Accuracy of different putty-wash impression techniques with various spacer thickness. Int J Clin Pediatr Dent. 2012;5(1):33-8.

2. Donovan TE, Chee WW. Current concepts in gingival displacement. J Prosthet Dent. 2004;91(6):566-71.

3. Goracci C, Ferrari M. Current perspectives on post systems: a literature review. Aust Dent J. 2011;56 Suppl 1:77-83.

4. Gonçalves FS, Popoff DAV, Castro CDL, Silva GC, Magalhães CS, Moreira AN. Dimensional stability of elastomeric impression materials: a critical review of the literature. Eur J Prosthodont Restor Dent. 2011;19(4):163-6.

5. Hillingburg HT, Sather DA, Wilson Jr EL, Cain JR, Mitchell DL, Blanco LJ et al. Fundamentals of fixed prosthodontics. 4th ed. Chicago: Quintessence; 2012.

6. Lima MBB, Magalhães APR, Teixeira TR, Lima PA, Martins WF, Decurcio RA, et al. Comparação de diferentes técnicas de moldagem com silicone de adição: estudo in vitro. Rev Odontol Bras Central. 2019;28(85):62-67.

7. Mahdi NA. Comparative evaluation of the dimensional accuracy of different putty-wash techniques using additional silicon impression material: in vitro study. J Al Rafidain Univ Coll. 2016;(38):141-61.

8. Marković D, Puskar T, Hadžistević M Potran M, Blažić L, Hodolic J. The dimensional stability of elastomeric dental impression materials. Contemp Mater. 2012;3(1):105-10.

9. Nagrath R, Lahori M, Agrawal M. A Comparative Evaluation of Dimensional Accuracy and Surface Detail Reproduction of Four Hydrophilic Vinyl Polysiloxane Impression Materials Tested Under Dry, Moist, and Wet Conditions-An In Vitro Study. J Indian Prosthodont Soc. 2014;14(Suppl 1):59-66.

10. Naumovski B, Kapushevska B. Dimensional Stability and Acuracy of Silicone - Based Impression Materials Using Different Impression Techniques - A Literature Review. Pril (Makedon Akad Nauk Umet Odd Med Nauki). 2017;38(2):131-138.

11. Ravi Teja BVH, Shylesh Kumar BS, Puttappa G. Evaluation of dimensional accuracy of two step putty wash impression technique using different spacers: an in-vitro study. Int J Health Sci. 2022;6(S1):9372-80.

12. Levartovsky S, Zalis M, Pilo R, Harel N, Ganor Y, Brosh T. The effect of one-step vs. two-step impression techniques on long-term accuracy and dimensional stability when the finish line is within the gingival sulcular area. J Prosthodont. 2014;23(2):124-33.

13. Tabassum S, Adnan S, Wöstmann B. Effect of different retraction materials on gingival sulcus width. J Prosthet Dent. 2008;100(6):468-73.

14. Wassell RW, Barker D, Walls AWG. Crowns and other extra-coronal restorations: impression materials and technique. Br Dent J. 2002;192(12):679-90.

15. Wöstmann B, Rehmann P, Trost D, Balkenhol M. Effect of different retraction and impression techniques on the marginal fit of crowns. J Dent. 2008;36(7):556-62.

16. Pardim NTG, Cunha MAP da. Materiais para Moldagem Funcional usados na Prótese Total: Revisão de literatura. Id Line Rev Mult Psic. 2019;13(48):465-75.

17. Ghanem RA, Nassani MZ, Baroudi K, Abdel Fattah A. Dimensional accuracy of different techniques used for complete-arch multi-implant impressions. J Investig Clin Dent. 2016;7(3):225-31.

18. Johnson GH, Craig RG. Accuracy of addition silicones as a function of technique. J Prosthet Dent. 1986;55(2):197-203.

19. Sudha BM, Rathod AS, Sulekha SG, Makandar S. Comparative evaluation of the dimensional accuracy of one-step versus two step putty wash impression techniques using two different commercially available addition silicone elastomeric impression materials - An In-vitro study. Uttar Pradesh J Zool. 2021;42(24):1458-64.

Downloads

Publicado

2025-08-31

Como Citar

Sepini, M., Reis, K. D., Gonçalves, L. A. C., & Goyatá, F. dos R. (2025). Moldagem Tripla com Silicones de Adição - Relato de Técnica. ARCHIVES OF HEALTH INVESTIGATION, 14(8), 2352–2357. https://doi.org/10.21270/archi.v14i8.6627

Edição

Seção

Original Articles